GESTRA SIP STEAM TRAPS SMK

GESTRA SIP STEAM TRAPS SMK

GESTRA SIP STEAM TRAPS SMK

SIP (steam-in-place) steam traps for aseptic and sterile applications

Thermostatic steam traps with minimum stagnant area for sterile and aseptic applications
For CIP (clean-in-place) and SIP (steam-in-place) processes, recognition of the aggregate state and an adequate steam trap reaction time are crucial factors. The STERIline membrane regulators employed in the SMK series react especially quickly to changing temperatures or operating states, thanks to their design, smaller surface and low weight.

USE: SIP STEAM TRAPS SMK

Extremely responsive steam trap – especially suitable for drainage in:

  • The pharmaceutical industry
  • Pure steam and ultrapure steam applications
  • CIP processes
  • Steam-in-place (SIP) processes

ADVANTAGES: SIP STEAM TRAPS SMK

  • Fast and precise STERIline thermostatic capsule
  • Achieves an almost constant system temperature
  • Minimum stagnant area
  • All parts in contact with medium are of high-quality stainless steel
  • The design principle allows installation with not many welded joints
  • Inner parts made of corrosion-resistant stainless steel
  • Functional unit can be replaced quickly and safely
  • Optional short design with clamp connection

METHOD OF OPERATION: SIP STEAM TRAPS SMK

When the system is coming to a stop:
As the temperature of the condensate falls, the control medium begins to condense.When the system is starting up:
The steam trap is in the open position. Air and cold condensate are discharged.
The steam trap is in the open position

The steam trap is in the open position

As the temperature of the condensate rises, the liquid control medium begins to evaporate.
The rise in pressure causes the thermostatic capsule to close just below boiling point
The steam trap is in the close position

The steam trap is in the close position

 